piNail Hardware (Prototype v2)

This file captures confirmed hardware details for the cigar-box prototype. Unknowns are marked TBD instead of guessed.

Prototype Summary

  • Enclosure: cigar box with integrated monitor in lid.
  • Input power: IEC C14-style AC inlet ("computer PSU" style).
  • Runtime controller: Raspberry Pi.
  • Heating channels: 2 coil channels (channel 2 wired but not yet validated in operation).

High-Level Power Architecture

AC input path

  1. AC inlet -> WiFi power switch.
  2. From WiFi switch output -> master mains switch for system.
  3. Master switch output branches:
    • Branch A: to main DC switching PSU (powers Pi/control electronics).
    • Branch B: to per-channel heater paths.

Control electronics power (DC)

  • Main DC PSU output provides control-side power for:
    • Raspberry Pi
    • Two thermocouple interface chips
    • Two SSR control sides
  • Nominal rail appears to be 5V (TBD: confirm exact PSU output voltage/current).

Heater power path (per channel)

  • After master switch, AC route per channel is:
    • fuse -> manual front-panel cutoff switch -> SSR load side -> coil connector power line
  • The opposite AC pole is routed from WiFi switch output directly to coil connector corresponding pole.
  • Ground/earth conductor is routed to coil connector grounds.

Channel/Signal Topology

  • Each channel has:
    • Thermocouple input (via MAX6675-type board)
    • SSR-driven AC heater output
    • Manual front panel power switch in series with heater path
  • Raspberry Pi drives each relay channel independently.
  • Thermocouple boards are connected to Pi GPIO.

GPIO Wiring (Clarified)

  • Thermocouple channel 1 (as originally noted): GPIO 5, GPIO 8, GPIO 7 (BCM numbering).
  • Thermocouple channel 2 was written as 11,12,13; this has been clarified as physical header pins.
  • Thermocouple channel 2 validated mapping:
    • Physical pins 11,12,13 => BCM 17,18,27.
    • Read test on BCM 17,18,27 returns valid MAX6675 words with open-thermocouple fault bit set when probe is disconnected (expected).
  • Alternate interpretation (BCM 11,12,13) returned all-zero frames and appears incorrect for channel 2.
  • Relay control (channel 2): GPIO 9 (BCM).
  • TBD: confirm relay control GPIO for channel 1 in this dual-channel prototype wiring doc.
  • Note: these dual-channel assignments differ from the current single-channel piNail2/config.json runtime pins.

Monitor Subsystem

  • Separate 12V power supply for the built-in monitor.
  • Short HDMI from Pi -> monitor.
  • Monitor considered optional for future versions.

Grounding Notes

  • Enclosure is non-metal (cigar box), so chassis bonding is not the main factor here.
  • Coil grounds are connected.
  • DC PSU ground is connected on the input-side ground scheme.
  • TBD: provide explicit earth/neutral/hot naming by region and verify continuity paths.

Protection and Switching (Current Understanding)

  • SSRs used for heater switching (TBD: exact model/rating).
  • Fuses appear to be 1A glass tube, one per channel (TBD: verify rating + slow/fast blow type).
  • Per-channel front switches are manual toggles.
  • WiFi switch has onboard button and can keep networked power state independent of channel switches.

Operational Behavior (as built)

  • You can power down Pi + nail supply via master mains switch while keeping WiFi switch infrastructure behavior available.
  • You can cut each coil independently with front-panel switches without shutting down software.
  • Channel 2 is wired but not yet fully tested under load.

Legacy/Prototype Context

  • Prototype v1: external Pi setup (pinout/relay/thermocouple cable to Pi), no built-in monitor.
  • Prototype v2: integrated Pi + wiring + optional integrated monitor.

Required TBDs Before Final Electrical Spec

  1. Coil connector pinout (both channels, exact pin numbering/function).
  2. Main DC PSU make/model and output spec (V/A).
  3. SSR model and AC load ratings.
  4. Fuse exact spec (amp, voltage, blow type, holder type).
  5. Exact line/neutral/earth routing confirmation diagram.
  6. Channel 2 validation checklist/results.