ops: mirror-35 resilver complete (0 errors); revert tunables; tank fully redundant

This commit is contained in:
2026-06-22 01:28:02 -04:00
parent fc744babad
commit ed3ce3fe81
@@ -84,7 +84,24 @@ yet** — stopped at "ready, awaiting bench hardware + go-ahead."
## Pending Work ## Pending Work
## ⏳ IN PROGRESS — tank redundancy restore (no new disk path) ## ✅ COMPLETE — tank redundancy restore (Jun 21) — no new disk used
**Done Jun 21 05:53**: resilver of mirror-35 finished, 4.12T in 5d14h52m, 0 errors.
- mirror-35 = healthy 2-way [`c382f4ac` ONLINE + `sde` (`c3663b1d`) ONLINE] + `sdg`
(`c37f4eff`) OFFLINE. Dead ZL2PNZ99 leg gone. Was effectively 1 healthy disk; now 2.
- ex-mirror-38 evacuated & gone. **Both redundancy holes closed, zero new disks.**
- Pool reports DEGRADED — ONLY because `sdg` is intentionally OFFLINE. Not a fault.
- Capacity cost: pool 549T→535T (~14T), 103T free @ 80%. Tunables reverted to stock.
### Remaining decisions (open)
1. **`sdg` endgame.** Now that mirror-35 has 2 healthy copies, the offline `sdg`
fallback is largely moot. Either: `zpool detach tank wwn-0x5000c500c37f4eff`
→ clean ONLINE pool + pull sdg for RMA (recommended), OR keep it offline until a
real replacement disk exists (pool stays DEGRADED-labeled). Seth's call.
2. CLAR200 F3 unlock — still pending, unblocked, needs bench (see below).
---
## (historical) IN PROGRESS — tank redundancy restore (no new disk path)
Seth chose to fix tank redundancy by **moving the bare ex-mirror-38 disk into Seth chose to fix tank redundancy by **moving the bare ex-mirror-38 disk into
mirror-35**, no new hardware. Started 2026-06-14 22:26. mirror-35**, no new hardware. Started 2026-06-14 22:26.